Branch
Aerospace industry
Application
Satellite tests. The satellite is submitted to outer space conditions in order to evaluate the reaction of its component parts.


Description of the equipment
Stainless steel chamber.
Chamber volume : 20m³.
Effective capacity : 12m³.
Length : 3000 mm.
Diameter : 2300 mm.
Specimen : 2100 x 1000 x 1400 mm.
Temperature : -135°C to +150°C.
Heat variation : 1,5°C/min linear.
Cold variation : 2°C/min linear.
Vacuum : 1.10-6 mbar, obtained in 4 hours.
Maximum vacuum : 1.10-8 mbar.
IR insolation : 2 500 W/m².
Controlled by Spirale Vs software
|